摘要:介 绍了应用有机高分子压电材料聚偏氟乙烯(PVDF)制作的压电传感器和结合电子线路进行的心音监测试验。压电薄膜传感器的设计利用了阻抗变换器,使 PVDF膜的高阻抗输出变为低阻抗输出,输出阻抗为3kW左右,并在后续电子线路中设计了高信噪比的放大电路,可对信号进行有效的放大;配合单片机、存储 器等芯片技术研制出初步监测心音心电信号的监测系统,能进行心音心电信号数据的采集、传送、处理。实验表明,该薄膜传感器与整机之间结构、性能完全匹配,该心音心电监测系统能够准确监测人体心音心电信号。
关键词:PVDF压电薄膜;阻抗变换器;心音传感器
Piezoelectric-Film Sensor And Its Application In The Heart Monitoring System
Abstract:The design and application of heart monitoring system of PVDF film piezoelectric sensors are presented. With the impedance converter, the piezoelectric film can detects the heart sounds in wide frequency spectrum. The amplifier increases the signals with flat frequency response. Using the detecting system designed with the microprocessor and flash memory, data is transported and recorded automatically. According to our experiment, the system analyzes the data well and truly. It is helpful in monitoring man’s heart.
Keywords:PVDF Piezoelectric film; impedance converter; phonocardia sensor
一、引言
心脏疾病是造成病残和死亡的常见疾病,在发达国家中,心血管系统疾病已成为最为常见的疾病和致死的重要原因,而随着我国人口老龄化,心血管疾病的比例也一年比一年高。
心血管诊断除了临床外,主要依靠医疗器械。心电和心音是检测心血管疾病的两种不同的手段,心电主要应用于心率失常及心肌缺血的定性与定量分析诊断,心血管药物的疗效评价。心音图能够有效的弥补心脏听诊的不足,将心脏听诊不能记录的心音信号或不容易分辨的信号用图形的形式记录下来,供医生分析使用[1]。心音图结合心电图,能够大大提高心血管疾病的鉴别和诊断水平,对于了解心血管功能,选择治疗,判断病理以及研究某些疾病的机理都提供了很有价值的资料,应用日益广泛。
对人体微弱生理信号的有效采集和处理一直是医疗器械领域的研究热点。目前有多种用于人体微弱信号采集的传感器,如压电陶瓷传感器、多普勒效应传感器等,但在结构和成本上 都存在一定的问题。目前有一种采用新型高分子压电材料聚偏氟乙烯研制的压电传感器,其结构简单,灵敏度高,能准确测量微弱的人体信号。我们将其应用于对人体心音信号的采集,研制了两通道的综合微型记录仪,分别动态记录心音信号和心电信号。实验表明,该薄膜传感器与整机之间结构、性能匹配,该心音心电监测系 统能够比较准确地监测分析人体心音心电信号,为系统以后的产品化奠定了基础。
二、压电薄膜传感器的设计
PVDF压电薄膜是一种新型的高分子压电材料,在医用传感器中应用很普遍[2,3]。它既具有压电性又有薄膜柔软的机械性能,用它制作压力传感器,具有设计精巧、使用方便、灵敏度高、频带宽、与人体接触安全舒适,能紧贴体壁,以及声阻抗与人体组织声阻抗十分接近等一系列特点[4],可用于脉搏心音等人体信号的检测。脉搏心音信号携带有人体重要的生理参数信息,通过对该信号的有效处理,可准确得到波形、心率次数等可为医生提供可靠的诊断依据。
压电薄膜传感器的设计主要考虑了传感器的灵敏度和信噪比,根据测量信号的频率和响应幅度,我们设计薄膜传感器的结构有如同图1所示的几种。在采集人体心音的信号时,由于心音的频响范围较宽,同时其输出的物理信号值也很微弱,采用硬质衬底和中空的设计。这样可以提高传感器中薄膜在收到心音信号时的形变量,从 而提高信号强度。这样结构设计的缺点是结构不牢固,使用时间长了需要校正。
PVDF压电薄膜的压电常数一般为D33=15×10-12C/N,g值比较高,但是具有很高的内阻抗,一般高达1012